The inlet sections are modular and available in three versions, J, VF and VFU; all fit Q200 and Q300 valves.
All have pump, tank, signal and servo pressure connection ports and measuring points for pump, signal and servo pressure.
The VF inlet sections can be used for variable and fixed pumps.
Simple conversion between fixed or variable pump by simply replacing plug, piston, spring and cover in one of the inlets
The inlet section has an integrated function that minimizes pressure surges in the hydraulic system.
Flow (from pump): Max. 300 l/min
Max. working pressure: 45,0 MPa (450 bar)
Measurement nipple standard: Tema system 100
Connections:
Pump (P): G 3/4″
Tank (T): G 3/4″
Signal (S): G 3/8″